{"product_id":"skycontrol_ground_system_remote_control","title":"SkyControl — Ground System Remote Control | WasherDrone","description":"\u003cdiv class=\"relative width-full grid items-start css-1xfg3jj\"\u003e\n\u003cdiv class=\"width-full height-full\"\u003e\n\u003cdiv class=\"\"\u003e\n\u003cdiv class=\"\"\u003e\n\u003cdiv class=\"flex-auto flex baymax\"\u003e\n\u003cdiv class=\"flex-auto width-full overflow-hidden pre-wrap break-word text-color-default text-size-default line-height-4 pt-nudge\"\u003e\n\u003cp\u003eSkyControl is a handheld radio remote that puts the WasherDrone ground system under the pilot's own hand. Pressure pump, water heater, water source selection and chemical injection rate are all commanded from the flight position, at ranges of up to 1,000 m in line of sight. Nobody has to stand at the machine, so a job that needed two people becomes a job for one. SkyControl is an optional addition: a SkyJet ground unit remains fully operable from its onboard panel, and the receiver can be fitted to units already in service.\u003c\/p\u003e\n\u003ch2\u003eKey benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne operator, not two.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo second person has to stand at the machine — and the largest recurring cost in a cleaning crew is the crew itself.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl where the work is.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWater source and chemical rate are changed the moment the surface calls for it, from where the operator can see the result.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1,000 m of working room.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ground unit can stand where access, water and power allow, not where an operator has to remain within earshot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo independent dosing channels.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach chemical injection channel is set continuously on its own control, so two products can be run at different rates in the same pass.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety logic stays on the ground.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterlocks and the safe state on link loss are enforced by the ground unit, not by the remote.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional and retrofittable.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSkyJet stays fully operable from its onboard panel. Add SkyControl at purchase or fit it later.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow it works\u003c\/h2\u003e\n\u003cp\u003eThe receiver sits inside the SkyJet ground unit and is wired to the pump, the heater, the inlet manifold valves and the dosing pumps. The handheld transmitter sends operator commands; whether a command is safe to carry out is decided by the ground unit itself.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe receiver is fitted inside the SkyJet ground unit — as a factory option or as a service retrofit to a unit already in the field.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommand:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFrom the flight position the operator selects the water source, starts the pressure pump and the heater, and sets each chemical injection rate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtect:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ground unit enforces every interlock and returns the system to a safe state if the radio link is lost.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eSystem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eGround system radio remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eWasherDrone SkyJet ground units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eReceiver fitted inside the ground unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRetrofit\u003c\/td\u003e\n\u003ctd\u003eYes, by WasherDrone authorised service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLink direction\u003c\/td\u003e\n\u003ctd\u003eTransmitter to receiver (one-way)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating range\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m, line of sight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eControl functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital channels\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue channels\u003c\/td\u003e\n\u003ctd\u003e2, continuously adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure pump\u003c\/td\u003e\n\u003ctd\u003eOn \/ off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater heater\u003c\/td\u003e\n\u003ctd\u003eOn \/ off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater source\u003c\/td\u003e\n\u003ctd\u003eThree-position select: mains, purified, mix tank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical dosing\u003c\/td\u003e\n\u003ctd\u003eTwo independent channels, rate adjustable in operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStop command\u003c\/td\u003e\n\u003ctd\u003eStops pump, heater and both dosing channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eInterlocks, enforced by the ground unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDry-run protection\u003c\/td\u003e\n\u003ctd\u003ePressure pump inhibited unless a water source is selected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDry-fire protection\u003c\/td\u003e\n\u003ctd\u003eWater heater inhibited without confirmed flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMix tank interlock\u003c\/td\u003e\n\u003ctd\u003eDosing inhibited when the pre-diluted mix tank is selected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoss of radio link\u003c\/td\u003e\n\u003ctd\u003ePump, heater and dosing stop; source valves close\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardwired stop\u003c\/td\u003e\n\u003ctd\u003eOn the ground unit, independent of the remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhat’s included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSkyControl handheld transmitter\u003c\/li\u003e\n\u003cli\u003eReceiver module for the SkyJet ground unit\u003c\/li\u003e\n\u003cli\u003eInstallation and wiring set\u003c\/li\u003e\n\u003cli\u003eOperator quick-reference guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBefore you deploy\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eRequires a WasherDrone SkyJet ground unit.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSkyControl commands a SkyJet ground unit and has no function on its own. The ground unit is a separate product and is not included.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIt does not control the aircraft.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSkyControl acts only on the ground system. The drone is flown with its own controller, on its own link, exactly as before.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRange is line of sight.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe stated range applies with a clear line of sight between transmitter and receiver. Buildings, scaffolding, vehicles and terrain reduce it; verify the working range on site before relying on it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe stop command is not an emergency stop device.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt is an operational command sent over a radio link. The hardwired emergency stop on the ground unit remains the safety device and must stay accessible during operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStatus is shown on the ground unit.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe link is one-way, so the remote does not display system state. Keep the ground unit's status indication in view, or confirm the state at the unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCrew size is an operational decision.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReducing the ground crew does not change the flight crew requirements set by your national aviation authority for the operation you are authorised to conduct.\u003c\/p\u003e\n\u003cp\u003eShipping and customs duties are not included.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Washer Drone Shop","offers":[{"title":"Default Title","offer_id":44259442491426,"sku":"WD-L1-SCT-4B2P","price":2000.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/1623\/0690\/files\/WD-SC-01_control_layout.jpg?v=1785836132","url":"https:\/\/shop.washerdrone.com\/products\/skycontrol_ground_system_remote_control","provider":"Washer Drone Shop","version":"1.0","type":"link"}