{"product_id":"skyjet-t-15","title":"WasherDrone SkyJet T-15 Three-Phase High-Pressure Hot Water Ground Unit","description":"\u003cp\u003eThe SkyJet T-15 is the three-phase ground power unit of a WasherDrone façade cleaning system. Its 5.5 kW motor delivers 15 L\/min at 150 bar — close to double the flow of the single-phase M-08 — for contractors working large surfaces continuously. It draws from four independent liquid sources and heats the flow to 90 °C through a diesel-fired 316L coil before delivering it up to 300 m to the airborne lance. A 400 V three-phase supply is required.\u003c\/p\u003e\n\u003ch2\u003eKey benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNearly double the flow.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e15 L\/min against 8 L\/min on the M-08 — the difference shows on large façades and multi-day contracts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSized for continuous duty.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA 5.5 kW three-phase motor runs at around 9 A, well inside its rating, rather than at the edge of a single-phase circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-operator capable.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith the optional SkyControl remote, the pilot runs pump, burner and auxiliaries from the flight position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot water beyond mains power.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA diesel-fired coil delivers the 78 kW of thermal load needed for 90 °C at full flow while the pump runs on site power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour independent inlets.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMains water, purified water and two chemical lines, opened independently and duplicated front and rear.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIn-house pump.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManufactured by WasherDrone; seal kits, valves and service parts come direct.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow it works\u003c\/h2\u003e\n\u003cp\u003eThe SkyJet stays on the ground while the drone works the façade. All fluid handling, heating and pressure generation happen inside the unit; the aircraft carries only the lance and the hose.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelect the source:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOpen one or more of the four manifold inlets: mains water, purified water, or either chemical line. Rear inlets mirror the front.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressurise and heat:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe plunger pump raises the fluid to 150 bar; the diesel burner brings it up to the temperature set on the panel thermostat, to 90 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeliver:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFluid leaves through the hose reel and travels up to 300 m to the lance carried by the drone.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ePerformance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking pressure\u003c\/td\u003e\n\u003ctd\u003e150 bar (~2,175 PSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow rate\u003c\/td\u003e\n\u003ctd\u003e15 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet temperature\u003c\/td\u003e\n\u003ctd\u003eUp to 90 °C at rated flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal load at 90 °C\u003c\/td\u003e\n\u003ctd\u003e78 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum hose length\u003c\/td\u003e\n\u003ctd\u003eUp to 300 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eElectrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e400 V, 3~, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power\u003c\/td\u003e\n\u003ctd\u003e5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRunning current\u003c\/td\u003e\n\u003ctd\u003e~9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit required\u003c\/td\u003e\n\u003ctd\u003e16 A 3-pole, with RCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary outlet\u003c\/td\u003e\n\u003ctd\u003e230 V, front panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eHeating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat source\u003c\/td\u003e\n\u003ctd\u003eDiesel-fired burner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat exchanger\u003c\/td\u003e\n\u003ctd\u003e316L stainless steel coil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel tank capacity\u003c\/td\u003e\n\u003ctd\u003e20 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel consumption\u003c\/td\u003e\n\u003ctd\u003e≈9 L\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeated autonomy\u003c\/td\u003e\n\u003ctd\u003e≈2 h continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eFluid handling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet manifold\u003c\/td\u003e\n\u003ctd\u003e5-way, 4 independent inlets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet duplication\u003c\/td\u003e\n\u003ctd\u003eFront and rear faces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet connections\u003c\/td\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-pressure outlet\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain\u003c\/td\u003e\n\u003ctd\u003eManual ball valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ePhysical \u0026amp; control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e500 × 1200 × 900 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (dry)\u003c\/td\u003e\n\u003ctd\u003e200 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame\u003c\/td\u003e\n\u003ctd\u003eSteel, lockable panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHose reel\u003c\/td\u003e\n\u003ctd\u003eIntegrated, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003ctd\u003eSkyControl (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformity\u003c\/td\u003e\n\u003ctd\u003e2006\/42\/EC Annex VIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhat’s included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSkyJet T-15 ground unit\u003c\/li\u003e\n\u003cli\u003e5-way inlet manifold, front and rear inlets\u003c\/li\u003e\n\u003cli\u003eDiesel burner, 316L coil and integrated hose reel\u003c\/li\u003e\n\u003cli\u003eUser manual, two-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBefore you deploy\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eThree-phase supply required.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA 400 V three-phase supply on a 16 A three-pole circuit with residual current protection. Sites without three-phase should use the SkyJet M-08.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGenerator operation.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllow at least 20 kVA. Direct-on-line starting draws six to seven times running current; a soft starter reduces this where supply is weak.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFuel autonomy at full flow.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAt 15 L\/min the burner consumes about 9 L\/h, so the 20 L tank gives roughly two hours of continuous heated operation. Plan refuelling into the work cycle.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDelivered conditions.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStated figures are measured at the unit; a 300 m run arrives about 20 K cooler and at lower pressure. Size hose bore for the intended run.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHeated operation.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDiesel only. Match the temperature rating of the connected hose and lance before running above ambient temperature.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWater, scale and chemicals.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClean the inlet filter and descale the coil periodically. Use only seal-compatible chemicals and flush the circuit after every cycle.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrost protection.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDo not expose to frost. Circulate antifreeze at the end of work in freezing conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHandling and service.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e200 kg dry — use lifting equipment. Check pump oil daily; service annually by an authorised technician.\u003c\/p\u003e\n\u003cp\u003eShipping and customs duties are not included.\u003c\/p\u003e","brand":"Washer Drone Shop","offers":[{"title":"Default Title","offer_id":46379228233762,"sku":"WD-L1-SJT-T15","price":12000.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/1623\/0690\/files\/SkyJet-Hero.jpg?v=1785856904","url":"https:\/\/shop.washerdrone.com\/products\/skyjet-t-15","provider":"Washer Drone Shop","version":"1.0","type":"link"}