{"product_id":"washerdrone-skyjet-e-power-high-pressure-hot-water-ground-unit","title":"WasherDrone SkyJet E-Power High-Pressure Hot Water Ground Unit","description":"\u003cp\u003eThe SkyJet E-Power is the ground power unit of a WasherDrone façade cleaning system. It draws from up to four independent liquid sources, raises the working fluid to 150 bar with an in-house manufactured plunger pump, and heats it to 90 °C through a diesel-fired 316L stainless steel coil before delivering it up to 300 m of hose to the airborne lance. Electric pump drive keeps the machine usable on ordinary site power, while diesel heating supplies the 42–78 kW of thermal energy no site electrical socket could provide. Two models cover single-phase and three-phase sites.\u003c\/p\u003e\n\u003ch2\u003eKey benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-operator capable.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith the optional SkyControl remote, the drone pilot commands the pump, the burner and connected auxiliaries from the flight position — no second person stationed at the machine.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot water where mains power cannot supply it.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHeating the flow to 90 °C needs 42 kW on the S-08 and 78 kW on the T-15 — far beyond any site electrical supply. A diesel-fired coil delivers it while the pump runs on ordinary power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour independent inlets.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA five-way manifold accepts mains water, purified water and two separate chemical mixes, each opened independently. Duplicate inlets on the rear face allow plumbing from either side.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIn-house pump, direct parts supply.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe high-pressure pump is manufactured by WasherDrone. Seal kits, valves and service parts come from the manufacturer rather than a third-party supply chain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo power configurations.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eS-08 runs from a single-phase 230 V supply at 15 A. T-15 runs from 400 V three-phase and delivers nearly double the flow for continuous high-throughput work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt to expand.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccepts SkyTank purified water storage, SkyMix chemical tanks and SkyControl remote operation. Front panel lettering can be cut with the customer's own logo on request.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow it works\u003c\/h2\u003e\n\u003cp\u003eThe SkyJet stays on the ground while the drone works the façade. All fluid handling, heating and pressure generation happen inside the unit; the aircraft carries only the lance and the hose.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelect the source:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOpen one or more of the four manifold inlets — mains water, purified water from a SkyTank, or either chemical line from a SkyMix. Rear-face inlets mirror the front so the unit can be plumbed from whichever side the site allows.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressurise:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe plunger pump raises the fluid to 150 bar. Working pressure is set at the panel regulator and read on the front gauge.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat, if required:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe diesel burner fires the coil and brings the flow up to the temperature set on the panel thermostat, to a maximum of 90 °C. Cold operation leaves the burner off.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeliver:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFluid leaves through the hose reel and travels up to 300 m to the lance carried by the drone.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ePerformance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking pressure\u003c\/td\u003e\n\u003ctd\u003e150 bar (~2,175 PSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow rate\u003c\/td\u003e\n\u003ctd\u003e8 L\/min (S-08) · 15 L\/min (T-15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet temperature\u003c\/td\u003e\n\u003ctd\u003eUp to 90 °C at rated flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal load at 90 °C\u003c\/td\u003e\n\u003ctd\u003e42 kW (S-08) · 78 kW (T-15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum hose length\u003c\/td\u003e\n\u003ctd\u003eUp to 300 m (hose bore dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eElectrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply — S-08\u003c\/td\u003e\n\u003ctd\u003e230 V, 1~, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power — S-08\u003c\/td\u003e\n\u003ctd\u003e3 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRunning current — S-08\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply — T-15\u003c\/td\u003e\n\u003ctd\u003e400 V, 3~, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power — T-15\u003c\/td\u003e\n\u003ctd\u003e5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRunning current — T-15\u003c\/td\u003e\n\u003ctd\u003e~9 A (11 A nameplate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary outlet\u003c\/td\u003e\n\u003ctd\u003e230 V socket, front panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eHeating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat source\u003c\/td\u003e\n\u003ctd\u003eDiesel-fired burner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat exchanger\u003c\/td\u003e\n\u003ctd\u003e316L stainless steel coil, 24 m × 1\/4\" bore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel tank capacity\u003c\/td\u003e\n\u003ctd\u003e20 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel consumption\u003c\/td\u003e\n\u003ctd\u003e≈5 L\/h (S-08) · ≈9 L\/h (T-15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eFluid handling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet manifold\u003c\/td\u003e\n\u003ctd\u003e5-way, 4 independent inlets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet duplication\u003c\/td\u003e\n\u003ctd\u003eFront and rear faces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet connections\u003c\/td\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-pressure outlet\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain\u003c\/td\u003e\n\u003ctd\u003eManual ball valve, front panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ePhysical \u0026amp; control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×D×H)\u003c\/td\u003e\n\u003ctd\u003e500 × 1200 × 900 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (dry)\u003c\/td\u003e\n\u003ctd\u003e200 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame\u003c\/td\u003e\n\u003ctd\u003eSteel chassis, lockable panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHose reel\u003c\/td\u003e\n\u003ctd\u003eIntegrated, manual crank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal control\u003c\/td\u003e\n\u003ctd\u003eMain switch, pump\/heat selector, thermostat, gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003ctd\u003eSkyControl handheld (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformity\u003c\/td\u003e\n\u003ctd\u003e2006\/42\/EC Annex VIII · EN ISO 12100 · EN 60204-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eModels\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eS-08\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Single-phase · 150 bar · 8 L\/min (230 V 1~, 3 kW, 15 A. Deployable wherever a robust single-phase circuit is available.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eT-15\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Three-phase · 150 bar · 15 L\/min (400 V 3~, 5.5 kW. Nearly double the throughput for continuous high-volume work.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat’s included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSkyJet E-Power unit in the selected model (S-08 or T-15)\u003c\/li\u003e\n\u003cli\u003e5-way inlet manifold with front and rear inlets\u003c\/li\u003e\n\u003cli\u003eDiesel burner and 316L stainless steel heating coil\u003c\/li\u003e\n\u003cli\u003eIntegrated hose reel\u003c\/li\u003e\n\u003cli\u003eFront control panel with gauge, thermostat and 230 V auxiliary outlet\u003c\/li\u003e\n\u003cli\u003eUser manual and two-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBefore you deploy\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical supply.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eS-08 requires a dedicated 20 A circuit with residual current protection; T-15 requires a 16 A three-pole supply with RCD. Extension leads must not be used. Confirm earthing before connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGenerator sizing.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOn generator supply, allow at least 10 kVA for the S-08 and 20 kVA for the T-15. Direct-on-line starting draws six to seven times running current; undersized generators will trip on start.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHose length and delivered conditions.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStated pressure and temperature are measured at the unit. Over long runs, friction and heat loss reduce both at the lance — a 300 m run typically arrives around 20 K cooler. Size hose bore for the intended run length and verify in the working configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHot-water compatibility.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHeated operation must be matched to the temperature rating of the connected hose and airborne lance. Verify the full delivery chain before running above ambient temperature.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFuel.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDiesel only, as stated on the identification plate. The 20 L tank supports approximately four hours of continuous heated operation on the S-08 and two hours on the T-15. Running dry damages the fuel pump.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWater quality and scale.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe inlet filter requires periodic cleaning. Hard water scales the heating coil over time and periodic descaling is required; purified water reduces both scaling and drying spots.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChemical handling.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse only chemicals compatible with the pump seals and the coil. Keep the two chemical lines separated for incompatible products and flush the high-pressure circuit with clean water after every chemical cycle.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrost protection.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDo not expose the unit to frost. Circulate antifreeze through the system at the end of work or before any extended break in freezing conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHandling and siting.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit weighs 200 kg dry — use mechanical lifting equipment for loading and positioning. Operate on firm level ground and never move the unit while it is running.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eService.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCheck pump oil daily and inspect for leaks weekly. Annual service by an authorised technician is required, including coil descaling and burner maintenance.\u003c\/p\u003e\n\u003cp\u003eShipping and customs duties are not included.\u003c\/p\u003e","brand":"Washer Drone Shop","offers":[{"title":"Monofaze \/ 150 Bar \/ 8 LPM \/ 3 kW","offer_id":46175958073378,"sku":"WD-L1-SKB-S08","price":10000.0,"currency_code":"EUR","in_stock":false},{"title":"Trifaze \/ 150 Bar \/ 15 LPM \/ 5.5 kW","offer_id":46175958106146,"sku":"WD-L1-SKB-T10","price":12000.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/1623\/0690\/files\/WhatsAppImage2025-11-18at09.27.20_2.jpg?v=1785701935","url":"https:\/\/shop.washerdrone.com\/products\/washerdrone-skyjet-e-power-high-pressure-hot-water-ground-unit","provider":"Washer Drone Shop","version":"1.0","type":"link"}